GPN1-12kV Ikurwaho AC Ibyuma byambaye imyenda ifunze
Imiterere y'ibidukikije
Ubushyuhe bwibidukikije: -25 ℃ ~ + 45 ℃, impuzandengo ya buri munsi: ≤35 ℃
Uburebure: 1000m (Bisanzwe);irashobora kugera kuri 4500m yo gutumiza bidasanzwe;
Ubushuhe bugereranije: impuzandengo ya buri munsi ≤95%, impuzandengo ya buri kwezi ≤ 90%;
Imbaraga z’umutingito degree8;
Ibihe byakoreshwa bigomba kuba bitarimo umuriro, ibisasu, ruswa hamwe no kunyeganyega gukabije.
Icyitegererezo
![icyitegererezo-12kV](http://www.gpswitchgear.com/uploads/model-12kV.jpg)
Ibiranga ibicuruzwa
1) Iki gicuruzwa kirakoreshwa mubyakozwe ubwacu GPVN-12kV / 17Kv / 24kV yashyizwemo cyangwa ikingira amaboko ya vacuum yamashanyarazi cyangwa ABB's VD4 vacuum yamashanyarazi.
)
3) Gukoresha icyuma cyiza cya aluminium-zinc ukoresheje ibyuma byerekana ibikoresho bya CNC byuzuye byateranijwe mu nama y'abaminisitiri, no gukoresha uburyo bwo kugonda kabiri, bizamura imbaraga z'inama y'abaminisitiri.
4) Ubuso bwumuryango ukoresheje epoxy resin electrostatike yifu ya spray, kurwanya ruswa, okiside, ingaruka hamwe no gukomera.
5) Inama y'Abaminisitiri yubatswe neza igerwaho nintwaro zuzuye, ibice bikora biratandukanye rwose.Iyo umuryango ufunze, irashobora kugera kumikorere ya break break yamashanyarazi.
6) Uburyo bwiza bwo gutwara ibinyabiziga, menyesha trolley hamwe no guhinduranya neza.
7) Gutunganya gahunda yibanze kugirango uhuze ibyifuzo bitandukanye byabakoresha, kandi ushoboze gahunda ya trolley ebyiri.
8) Umuvuduko wihuse wubutaka nubutaka bugufi, no kugera kubikorwa byamashanyarazi (Moteri).
9) Uburyo bworoshye kandi bunoze "Uburyo butanu bwo guhuza umutekano" burashobora gukumira byimazeyo gukoresha nabi no kurinda umutekano wumukoresha.
10) Switchgear ni iy'ubwoko bwa Arc, hejuru ya bisi, icyumba cya Vacuum cyacamo ibice, hamwe na kabili ya kabili ifite ibikoresho byo gutabara.
11) Igice cya kabili gifite umwanya uhagije, kirashobora guhuzwa byoroshye nubwinshi bwinsinga, kandi urebe neza ko uburebure bwububiko bwa kabili.
12) Igipimo gikomeye cyo kurinda (IP4X), kugirango wirinde neza ibintu by’amahanga cyangwa gutera udukoko.
13.
14) Menya GB3906, GB / T11022, DL404 na IEC60298, IEC62271-1, kandi ukoresheje ikizamini cyuzuye cyubwoko bwikizamini hamwe nikizamini cya plateau (3000 m).
15) Yatsinze ibizamini bya electromagnetic ihuza ibizamini bya laboratoire.
A.Ibisobanuro bya tekiniki Kuri 12Kv ya switchgear
Ingingo | Igice | Amakuru | |
Ikigereranyo cya voltage | kV | 6 ~ 12 | |
Ikigereranyo cyagenwe | Hz | 50/60 | |
Ikigereranyo cyubu | A | 630 ~ 4000 | |
Urwego rwo kugereranya | 1min inshuro nyinshi (Icyiciro ku isi / hakurya yuguruye) | kV | 42/48 |
Inkuba ihangane na voltage (Icyiciro ku isi / hakurya yuguruye) | kV | 75/85 | |
Busbari nkuru yagaragaye igezweho | A | 1250.1600.2000.2500.4000 | |
Sub-busbar yagenwe ikigezweho | A | 630,1250,1600,2000,2500,3150 | |
Ikigereranyo cyigihe gito uhangane nubu (4s) | kA | 16,20,25,31.5,40,50 | |
Ikigereranyo cyo hejuru cyihanganira ikigezweho | kA | 40,50,63,80,100,125 | |
Impamyabumenyi yo gukingira | Funga IP4X, IP2X (umuryango wa VCB warafunguwe) | ||
Igipimo cyerekana (ubugari / ubujyakuzimu / uburebure) | mm | 650 (800.1000) / 1500 (1300.1670.2000) / 2300 | |
Ibiro | kg | 500 ~ 1200 |
Igishushanyo mbonera cya cubicle 630A ~ 1250A
![12kV-1](http://www.gpswitchgear.com/uploads/12kV-1.jpg)
Igishushanyo mbonera cya cubicle 1600A ~ 4000A
![12kV-2](http://www.gpswitchgear.com/uploads/12kV-2.jpg)
B.Ibikoresho byinshi bya tekinike ya 17.5kV ya switchgear
Oya. | Izina | Igice | Amakuru | |
1 | Ikigereranyo cya voltage | kV | 15 / 17.5 | |
2 | Urwego rwo kugereranya | Iminota 1 yumuriro wihanganira voltage (RMS) | kV | 50 |
Kumurika impulse kwihanganira voltage (impinga) | 95 | |||
3 | Ikigereranyo cyubu | A | 630 ~ 4000 | |
4 | Ikigereranyo kigufi-kizunguruka gifungura amashanyarazi | kA | 50 | |
5 | Ikigereranyo cyingufu zingana | Hz | 50/60 | |
6 | Ikigereranyo kigufi-kizunguruka gikora amashanyarazi (impinga) | kA | 130 | |
7 | Ikigereranyo cyo hejuru cyihanganira ikigezweho | kA | 130 | |
8 | Ikigereranyo kigufi-cyihangane nubu | kA | 50 | |
9 | Ubuzima bw'amashanyarazi | ibihe | 20 | |
10 | Ikigereranyo kigufi-kizunguruka cyigihe | s | 4 | |
11 | Ubuzima bwa mashini bwa VCB | ibihe | 10000 | |
12 | Urwego rwo kurinda cubicle | Funga IP4X, IP2X (umuryango wa VCB warafunguwe) | ||
13 | Ibipimo byerekana (W * D * H) | mm | 800/1000 * 1500/1670 * 2300 | |
14 | Ibiro | kg | 500 ~ 1200 |
C. Ibisobanuro bya tekiniki ya 24kV ya switchgear
Ingingo | Igice | Amakuru | |
Ikigereranyo cya voltage | kV | 24 | |
Ikigereranyo cyagenwe | Hz | 50/60 | |
Ikigereranyo cyubu | A | 630,1250, 1600, 2500, 3150, 4000 | |
Urwego rwo kugereranya | 1min inshuro nyinshi (icyiciro ku isi / hakurya ifunguye) | kV |
65 |
Inkuba ihangane na voltage (icyiciro ku isi / hakurya ifunguye) | kV |
125 | |
Ikigereranyo cyigihe gito uhangane nubu (4s) | kA | 20, 25, 31.5 | |
Ikigereranyo cyo hejuru cyihanganira ikigezweho | kA | 50, 63, 80 | |
Impamyabumenyi yo gukingira | Umugereka: IP4X, umuryango ufunguye: IP2X | ||
Ibipimo byerekana (ubugari x ubujyakuzimu x uburebure) | mm | 1000 (800) x1820 (1500) x2430 (2300) | |
Ibiro | kg | 1200-1500 |
1. Ubushobozi buke bwumuzunguruko wa CT bugomba gusuzumwa ukundi;
2. Igishushanyo cyinyuma cyimbere gisohoka kigomba kugira cubicle yinyongera.
Imiterere igishushanyo mbonera cya GPN1-24kV igishushanyo cyibice byigaburo
![24kV](http://www.gpswitchgear.com/uploads/24kV.jpg)