GPR-24 (12) kV Urukurikirane Impeta Igice kinini Guhindura
Incamake
GPR-24 ikurikirana Impeta nkuru nigice cyagutse, SF6 ikinguye, ifite voltage ya 12 & 24 kV.Ibice byose bya HV bizima bikubiye mu kigega cya gaze gikoresha umwuka, gikozwe mu byuma bidafite ingese ya 3mm.Inteko yose yo guhinduranya ni SF6 ikingiwe, kandi idafite imbaraga zose zituruka hanze, ikemeza ko ari iyo kwizerwa gukomeye kwa serivisi no kuyitaho kubuntu.Mugihe wacometse mubwoko bwa busbar kwaguka, GPR-24 ikurikirana Impeta nyamukuru Igice gishobora kuba cyubusa hamwe na modularisation yuzuye.Kwiyongera kwa busbar byatsinze ubwoko bwikizamini cyingufu nubushyuhe bwumuriro, kandi burakingiwe kandi burakingiwe, bwerekana ubwizerwe numutekano muke.Urwego rwa GPR-24 Urwego rukuru rukwiranye numuyoboro wose wa MV kugeza kuri kV 24, sitasiyo zose zikoresha amashanyarazi, amashanyarazi akwirakwizwa mumashanyarazi yose yinganda, nkinganda zikomoka kuri peteroli, inganda za metallurgie nubucukuzi bwamabuye y'agaciro, hamwe na transfert zose hamwe nimbaraga z'umuyaga. Sisitemu.
Ibiranga
1. Uburyo bunoze bwo gutunganya ikigega cya gaze
Sisitemu igenzurwa na sisitemu yo gukata no gukubita sisitemu hamwe na sisitemu yo gusudira ya metero eshatu na eshanu-axis ya laser yo gusudira yatumijwe mu Budage kugira ngo gaze ikomeze kandi ihure n'ibigega byose bya gaze.
Sisitemu yuzuye kandi yuzuye ya helium yamenetse, yakozwe na SEILER Vakuumtechnik GmbH, binyuze mugutahura imyuka ya Helium ikoresheje mass spectrograph, izana igipimo cyo kumeneka gazi kumwaka kugera munsi ya 0.02%, bigatuma ubuzima bwa tank ya gaze yimyaka irenga 30.
Tekinike yambere yo gutunganya ibice.
Epoxy resin ibice byose byashizwemo, harimo ninkingi yiziritse, bikozwe na epoxy resin vacuum ivanga / sisitemu ya gelatinizing ivuye Hedrich (Ubudage).
Umuyoboro wa busbar, umuhuza wa kabili, ucomeka-wanyuma hamwe nibindi bice bya silicone reberi yakozwe na sisitemu yakozwe na sisitemu yuzuye-igenzurwa na digitike ya silicone reberi ivanga / sisitemu ya gelatinizing ivuye muri VOGEL (Ubusuwisi).
2. Ibisubizo byiza kubicuruzwa
Hamwe nimiterere mito kandi yoroheje, ibice byibanze bikora K, T, V, B na C bifite ibipimo bimwe: 350 * 800 * 1380 mm (ubugari * ubujyakuzimu * uburebure).
Ibisubizo byuzuye:
Imiterere imwe: imitwaro yo kumenagura ibice, guhinduranya-fuse, icyuma cyumuzunguruko wa vacuum, igice cya bisi ya bisi, igice cya kabili, ibipimo, nibindi.
Guhagarika verisiyo irashobora kuba igizwe nibice bibiri, bitatu, bine, bitanu cyangwa bitandatu.
Ibice bimwe hamwe na verisiyo yo guhagarika irashobora guhuzwa na busbar ihuza byoroshye.
3. Guhuza cyane n'ibidukikije
Sisitemu y'ibanze itwara kashe yuzuye muri tank ya gaze ya SF6 kandi ntabwo izaterwa nibidukikije byo hanze, bititaye ku ngaruka z'ikime, umukungugu, igihu cy'umunyu, n'ibindi. .
12kV Amakuru ya tekiniki
Ibisobanuro | Igice | Igice cya LBS | Igice cya fuse | Igice cya VCB | Igice cya Busbar | |
Ikigereranyo cya voltage | kV | 12 | 12 | 12 | 12 | |
Imbaraga zumuriro zihanganira voltage (1min) | Icyiciro kugeza icyiciro / isi | kV | 42 | 42 | 42 | 42 |
Kurenga intera yitaruye | kV | 48 | 48 | 48 | 48 | |
Impulse ihangane na voltage | Icyiciro kugeza icyiciro / isi | kV | 75, (95) * | 75, (95) * | 75, (95) * | 75, (95) * |
Kurenga intera yitaruye | kV | 85, (110) * | 85, (110) * | 85, (110) * | 85, (110) * | |
Ikigereranyo cyagenwe | Hz | 50,60 | 50,60 | 50,60 | 50,60 | |
Ikigereranyo cyubu | A | 630 | ① | 630 | 630 | |
Ikigereranyo kigufi cyumuzunguruko | kA |
| ② | 20, (25) * |
| |
Ikigereranyo cyigihe gito uhangane nubu | kA / s | 20/3, (20/4, 25/1) * |
| 20/3, (20/4, 25/3) * | 20/3, (20/4, 25/1) * | |
Ikigereranyo cyo hejuru cyihanganira ikigezweho | kA | 50, (63) * |
| 50, (63) * | 50, (63) * | |
Urutonde rugufi ruzunguruka rukora amashanyarazi | kA | 50, (63) * | ② | 50, (63) * | 50, (63) * | |
Ikigereranyo cyo kwimura | A |
| 1800 |
|
| |
Ikigereranyo gikora imitwaro yamenetse | A | 630 |
|
| 630 | |
Ikigereranyo gifunze loop yamenetse | A | 630 |
|
| 630 | |
5% bagereranije ibikorwa bikora kumeneka | A | 31.5 |
|
| 31.5 | |
Urutonde rukurikirana |
|
|
| O-0.3s-CO-180s-CO |
| |
Ubuzima bwa mashini | Ops. | 5000 | 5000 | 10000 | 5000 | |
Ubuzima bw'amashanyarazi |
| E3 |
| E2 | E3 | |
Umubyimba w'icyuma | mm | 3.0 | ||||
Ikigereranyo cya SF6igitutu | kPa | 30 (kuri 20 ℃, 101.3kPa) | ||||
Igipimo cyumwaka | < 0,02% | |||||
Ikizamini cyo gutunganya amazi | 12kV amasaha 24 (kuri 30 kPa munsi y'amazi) | |||||
Ikizamini cyimbere | 20kA 1s | |||||
Impamyabumenyi yo gukingira | Ikigega cya gaze | IP 67 | ||||
Ufite fuse | IP 67 | |||||
GPR |
| IP 4X |
24kV Amakuru ya tekiniki
Ibisobanuro | Igice | Igice cya LBS | Igice cya fuse | Igice cya VCB | Igice cya Busbar | |
Ikigereranyo cya voltage | kV | 24 | 24 | 24 | 24 | |
Imbaraga zumuriro zihanganira voltage (1min) | Icyiciro kugeza icyiciro / isi | kV | 50, (65) * | 50, (65) * | 50, (65) * | 50, (65) * |
Kurenga intera yitaruye | kV | 64, (79) * | 64, (79) * | 64, (79) * | 64, (79) * | |
Impulse ihangane na voltage | Icyiciro kugeza icyiciro / isi | kV | 95, (125) * | 95, (125) * | 95, (125) * | 95, (125) * |
Kurenga intera yitaruye | kV | 110, (145) * | 110, (145) * | 110, (145) * | 110, (145) * | |
Ikigereranyo cyagenwe | Hz | 50, 60 | 50, 60 | 50, 60 | 50, 60 | |
Ikigereranyo cyubu | A | 630 | ① | 630 | 630 | |
Ikigereranyo kigufi cyumuzunguruko | kA |
| ② | 20 |
| |
Ikigereranyo cyigihe gito uhangane nubu | kA / s | 20/3, (20/4) * |
| 20/3, (20/4) * | 20/3, (20/4) * | |
Ikigereranyo cyo hejuru cyihanganira ikigezweho | kA | 50 |
| 50 | 50 | |
Urutonde rugufi ruzunguruka rukora amashanyarazi | kA | 50 | ② | 50 | 50 | |
Ikigereranyo cyo kwimura | A |
| 1400 |
|
| |
Ikigereranyo gikora imitwaro yamenetse | A | 630 |
|
| 630 | |
Ikigereranyo gifunze loop yamenetse | A | 630 |
|
| 630 | |
5% bagereranije ibikorwa bikora kumeneka | A | 31.5 |
|
| 31.5 | |
Urutonde rukurikirana |
|
|
| O-0.3s-CO-180s-CO |
| |
Ubuzima bwa mashini | Ops. | 5000 | 5000 | 10000 | 5000 | |
Ubuzima bw'amashanyarazi |
| E3 |
| E2 | E3 | |
Umubyimba w'icyuma | mm | 3.0 | ||||
Ikigereranyo cya SF6 | kPa | 30 (kuri 20 ℃, 101.3kPa) | ||||
Igipimo cyumwaka | < 0,02% | |||||
Ikizamini cyo gutunganya amazi | 24kV amasaha 24 (kuri 30 kPa munsi y'amazi) | |||||
Ikizamini cyimbere | 20kA 1s | |||||
Impamyabumenyi yo gukingira | Ikigega cya gaze | IP 67 | ||||
Ufite fuse | IP 67 | |||||
GPR | IP 4X |
Inyandiko:
Current Ikigereranyo cyagenwe cya switch-fuse biterwa nurwego rwa fuse: ≤100A
② Ikigereranyo kigufi cyumuzingi kumena / gukora amashanyarazi ya switch-fuse biterwa nurwego rwa fuse
* Indangagaciro mumutwe nibisabwa byihariye, nyamuneka hamagara uwabikoze cyangwa utanga amakuru kubindi bisobanuro
Incamake ya GPR24
1. Ubwoko bumwe bwa tank
Icyitonderwa:
1. Indangagaciro mumutwe zanditseho "*" nibicuruzwa kuri 24kV, inshuro yumuriro wihanganira voltage ya 65 / 79kV;
2. Niba hari ibice byinshi byisumbuyeho muburyo bwimiterere, ikindi gice cyabyo gishobora gushyirwaho hejuru yikibaho, uburebure bwacyo ni 400mm.
2. GPR24 Guhagarika ubwoko-1 kuri 12kV & 24kV (ingufu z'umuriro zihanganira voltage: 50 / 64kV)
Inyandiko:
Niba hari ibice byinshi byisumbuyeho muburyo bwimiterere, igice cyinyongera kuri bo gishobora gushyirwaho hejuru ya GPR, uburebure bwacyo ni 400mm