12/24 / 40.5kV Inteko yo gufunga no gufatanya
Shutter Inteko 5GP.320.010 Igishushanyo mbonera
(Ubugari bwa 800mm hagati-yashyizwe hagati ya switchgear)
Inteko ya Shutter 5GP.320.010 Urutonde
Oya. | Izina | Igishushanyo oya. | Qty.(pc / gushiraho) |
1 | Gushyigikira iburyo | 8GP.123.011 | 1 |
2 | Isahani iburyo | 5GP.235.011 | 1 |
3 | Kwerekana ikirango | 8GP.866.014 | 1 |
4 | Ihuza ry'ibumoso | 5GP.235.010 | 1 |
5 | Ibumoso bushyigikira | 8GP.123.010 | 1 |
6 | Kuzenguruka | 5GP.174.016.1 (Kuri VD4) | 2 |
5GP.174.016.2 (Kuri GPVN) | |||
5GP.174.016.3 (Kuri VB2) | |||
7 | Irembo ryo gufunga | 8GP.320.010 | 1 |
8 | Guhagarika jammed 8 | DK-8 | 8 |
9 | Isahani | 8GP.123.013 | 3 |
Oya. | Izina | Igishushanyo oya. | Qty.(pc / gushiraho) |
10 | Kuzenguruka | 5GP.174.017.1 (Kuri VD4, 40kA) | 2 |
5GP.174.017.2 (Kuri VD4, 31.5kA) | |||
5GP.174.017.3 (Kuri GPVN) | |||
5GP.174.017.4 (Kuri VB2) | |||
11 | Kwerekana ikirango | 8GP.866.012 | 1 |
12 | Kwerekana ikirango | 8GP.866.013 | 2 |
13 | Isahani | 8GP.123.012 | 3 |
14 | Shitingi yo hejuru | 8GP.320.011 | 1 |
15 | Inkoni yo kuyobora | 8GP.234.011 (Kuri VD4, GPVN) | 2 |
8GP.234.011.1 (Kuri VB2) | |||
16 | Guhagarara | 8GP.210.011 | 2 |
Ibindi bisobanuro byafunguye urutonde
Kode | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Ubugari bw'Abaminisitiri | 650mm | 700mm | 840mm | 900mm | 1000mm |
Irembo ryo hejuru | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Irembo | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Inteko ya Shutter 5GP.320.011
(Ubugari bwa 1000mm hagati-yashyizwe hagati ya switchgear)
Shutter Mechanism Igikoresho 5GP.320.011 Urutonde
(Ubugari bwa 1000mm hagati-yashyizwe hagati ya switchgear)
Oya. | Izina | Igishushanyo oya. | Qty.(pc / gushiraho) |
1 | Gushyigikira iburyo | 8GP.123.276 | 1 |
2 | Isahani iburyo | 5GP.235.012 | 1 |
3 | Kwerekana ikirango | 8GP.866.014 | 1 |
4 | Icyapa cyibumoso | 5GP.235.013 | 1 |
5 | Ibumoso bushyigikira | 8GP.123.275 | 1 |
6 | Ihuriro ryo gusudira | 5GP.174.281 | 2 |
7 | Hasi | 8GP.320.273 | 1 |
8 | Guhagarika jammed 10 | DK-10 | 8 |
Oya. | Izina | Igishushanyo oya. | Qty.(pc / gushiraho) |
9 | Isahani | 8GP.123.278 | 3 |
10 | Guhuza gusudira hamwe | 5GP.174.282 | 2 |
11 | Kwerekana ikirango | 8GP.866.012 | 1 |
12 | Kwerekana ikirango | 8GP.866.013 | 2 |
13 | Isahani | 8GP.123.277 | 3 |
14 | Shitingi yo hejuru | 8GP.320.274 | 1 |
15 | Inkoni yo kuyobora | 8GP.234.272 | 2 |
16 | Guhagarara | 8GP.210.011 | 2 |
Ibindi bisobanuro byafunguye urutonde
Kode | 5GP.320.011.1 | 5GP.320.011 / JY | 5GP.320.011.2 | 5GP.320.011.3 |
Ubugari bw'Abaminisitiri | 800mm | 1000mm (Gukingira) | 1100mm | 1200mm |
Irembo ryo hejuru | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Irembo | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Icyitonderwa: 5GP.320.
Igikoresho cyo guhinduranya ibikoresho byo guhuza ibikoresho (Kubikorwa byo guhuza amaboko yo guhuza) 5GP.363.010.1 igishushanyo mbonera
Amabwiriza yo Guhuza Igikoresho
Igikoresho cyo guhuza cyongewemo gihuza urugi rwinyuma rwashizweho hashingiwe ku mwimerere wa 5GP.363.010 igikoresho cyo guhuza ibikoresho cyo guhuza ibikoresho.Nukuvuga ko, nyuma yubutaka bwubutaka bumaze gufungurwa no gukingura urugi rwinyuma (icyapa gifunga), guhuza kwambere kwarashobora gukora icyuma cyubutaka, ariko iyi sano ntishobora.Ugomba kubanza gufunga umuryango winyuma (icyapa gifunga) kugirango ukore icyuma cyubutaka.
Amahame yimikorere yigikoresho cyo guhuza yahinduwe nimero 24 yo gufunga icyerekezo cyerekanwe iburyo kandi wongeyeho isoko hashingiwe kuri 5GP yambere .363.010.Iyo umuryango winyuma (icyapa gifunga) ufunguye, urutoki rwo gufunga rwinjira mu mwobo wa kare wa kabili (usabwa ubunini bwa 35X35), icyuma gishobora gukoreshwa.
Igikoresho cyo guhinduranya ibikoresho byo guhuza ibikoresho (Kubikorwa byo guhuza amaboko)
5GP.363.010.1 urutonde rwateguwe.
Oya. | Izina | Igishushanyo oya. | Qty.(pc / gushiraho) |
1 | Kubyara | 8GP.263.011 | 1 |
2 | Umurenge | 8GP.192.010 | 1 |
3 | Umurenge | 8GP.192.011 | 1 |
4 | Axis | 8GP.210.014.1 | 2 |
5 | Umurenge | 8GP.151.041 | 1 |
6 | Axis | 8GP.211.061 | 1 |
7 | Umurenge | 8GP.151.039 | 1 |
8 | Axis | 8GP.211.062 | 1 |
9 | Bolt M5 × 12 | GB70-85 | 1 |
10 | Umurenge | 8GP.151.042 | 1 |
11 | Umurenge | 8GP.151.043 | 1 |
12 | Inkoni yo gukora | 8GP.200.013.1 (Uburebure 1432 kuburebure bwa kabili 1500) | 1 |
8GP.200.013.2 (Birebire 1590 kuburebure bwa guverinoma 1660) | 1 | ||
13 | Isahani | 8GP.161.058 | 1 |
8GP.161.058.1 (Kuburyo bwo guhitamo) | 1 |
Oya. | Izina | Igishushanyo oya. | Qty.(pc / gushiraho) |
14 | Igipfukisho | 8GP.017.011.1 | 1 |
15 | Agace | 5GP.043.022 | 1 |
16 | Isahani | 8GP.161.059 | 1 |
17 | Igitabo | 8GP.143.010 | 2 |
18 | Axis | 8GP.211.058 | 1 |
19 | Guhagarara | 8GP.211.057 | 3 |
20 | Shingiro shingiro | 8GP.043.019 | 1 |
21 | Gufunga kwerekana | 8GP.866.010 | 1 |
22 | Iteraniro ryinkoni | 5GP.233.030.1 | 1 |
5GP.233.030.3 (Kuburyo bwo guhitamo) | 1 | ||
23 | Gufungura kwerekana | 8GP.866.011 | 1 |
24 | Gufunga amaboko | 8GP.211.201 | 1 |
25 | Isahani yinyo | 8GP.151.044 | 1 |
26 | Axis | 8GP.211.060 | 2 |
27 | Tag | 8GP.860.010 | 1 |
28 | Amasoko y'ingutu | 8GP.282.201 | 1 |
29 | Gufunga amaboko atunganya Bolt | 8GP.920.002 | 1 |
Icyitonderwa:
1. No 1 ~ 12 reba urupapuro rwabanjirije.
2. No.Niba ukeneye intera iri hagati ya 80mm nyamuneka reba urupapuro rwa 17 amabwiriza yo guteranya inteko, hanyuma ugaragaze igihe utumiza.
Igikoresho cyo guhinduranya ibikoresho byo guhuza ibikoresho (Kubikorwa byo gutwara ibikoresho bya bevel) 5GP.577.1001
Igikoresho cyo guhinduranya ibikoresho byububiko (Kubikorwa bya bevel gear Drive) 5GP.577.1001 urutonde
Oya. | Izina | Igishushanyo oya. | Qty.(pc / gushiraho) |
1 | Kubyara | 8GP.263.011 | 1 |
2 | Isahani yo guhagarara | 8GP.151.084 | 2 |
3 | Axis | 8GP.210.014.1 | 2 |
4 | Umurenge | 8GP.151.041 | 1 |
5 | Axis | 8GP.210.014.2 | 1 |
6 | Bolt M 5X12 | GB70-85 | 1 |
7 | Umurenge | 8GP.151.042 | 1 |
8 | Umurenge | 8GP.151.043 | 1 |
9 | Axis | 8GP.210.014.3 | 1 |
Oya. | Izina | Igishushanyo oya. | Qty.(pc / gushiraho) |
10 | Guhagarara | 8GP.210.322 | 1 |
11 | Inkoni yo gukora | 8GP.174.214 | 1 |
12 | Igipfukisho | 8GP.017.011.2 | 1 |
13 | Shingiro shingiro | 5GP.043.022 | 1 |
14 | Igitabo | 8GP.143.010 | 2 |
15 | Isahani | 8GP.161.059 | 1 |
16 | Isahani | 8GP.161.058 | 1 |
17 | Isahani yinyo | 8GP.151.044 | 1 |
18 | Tag | 8GP.860.010 | 1 |
Icyitonderwa: 1. Ubu buryo bukeneye gufunga urugi rwo hasi, nyamuneka sobanura igihe utumiza.