Ibipimo na Metero Ingufu
Ubwoko Ibisobanuro
Andika | Ingingo | Uburyo bwo kwerekana | Imbaraga | Gufunga ingaragu | Gufunga inshuro ebyiri | Shyiramo | Kwigenga | Igipimo | Ingano yo gutema | Igishushanyo | |
kugenzura | kuvugana | kugenzura | |||||||||
Ubwoko bwubatswe | GPXN-Q | Kanda | - | 96 × 48 × 88 | 91 × 44 | 3 | |||||
GPXN-T | Kanda | 96 × 48 × 55 | 91 × 44 | 3 | |||||||
Swg. | GPXN1-Q | Umucyo | - | - | 96 × 48 × 88 | 91 × 44 | 1 | ||||
GPXN1-T | Umucyo | - | 96 × 48 × 55 | 91 × 44 | 1 | ||||||
GPXN4-Q | Kanda | - | - | 144 × 48 × 104 | 138 × 44 | 4 | |||||
GPXN4-T | Kanda | - | 144 × 48 × 104 | 138 × 44 | 4 | ||||||
GPXN5-Q | Kanda | - | - | 96 × 48 × 88 | 91 × 44 | 2 | |||||
GPXN5-T | Kanda | - | 96 × 48 × 55 | 91 × 44 | 2 | ||||||
Imashini imwe hamwe n'ibipimo 2 | GPXN4-Q / M. | Kanda | - | - | 144 × 48 × 104 | 138 × 44 | 4 | ||||
GPXN4-T / M. | Kanda | - | 144 × 48 × 104 | 138 × 44 | 4 | ||||||
GPXN4-T / Z. | Kanda | 144 × 48 × 104 | 138 × 44 | 4 | |||||||
Ubwoko bwihariye | GPXN1-Q / CS | Umucyo | - | - | - | 96 × 48 × 88 | 91 × 44 | ||||
GPXNP1-Q / W. | Umucyo | - | - | - | 96 × 48 × 88 | 91 × 44 | 1 | ||||
GPXN-Q / LCS | Umucyo | - | - | 96 × 48 × 88 | 91 × 44 | 3 |
Ikimenyetso cya Voltage Ikoreshwa muri Impeta Nkuru
Ikimenyetso cya voltage ikoreshwa hamwe na insulator kugirango yerekane amashanyarazi yumuriro wa voltage.
Ikurikiranwa rya voltage ikomeza GPXN9-C ikoreshwa hamwe nicyerekezo cyerekana amashanyarazi.Intera yumwobo wa power-check terminal ni 14mm cyangwa 19mm.
Kugereranya icyiciro GPXN-C ikoreshwa hamwe nicyerekezo cyerekana amashanyarazi yumuriro wumuriro mwinshi hamwe no kugenzura icyiciro cyibikoresho byamashanyarazi.
Kugenzura imbaraga: igereranya ryicyiciro winjiza mubutaka cyangwa ubundi buryo bwibikoresho byumuvuduko mwinshi.
Icyiciro-kigenzura: igereranya ryicyiciro shyiramo icyiciro kimwe cyingufu-igenzura ya terefone ebyiri zikoresha ingufu nyinshi, niba urumuri rwa LED rwaka, byerekana ko icyiciro cyo kugerageza gifite amashanyarazi.
Icyerekezo cy'umwanya
Ibipimo byerekana imyanya birashobora kwigana imikorere yimikorere nuburyo ibintu byahinduwe nka switch na break break muri sisitemu y'amashanyarazi.Ikoreshwa cyane muburyo bwose bwo kwigana ikibaho cyo kugenzura hagati hamwe na panne ya switchgear mumashanyarazi, sitasiyo yamashanyarazi na sitasiyo ya transformateur.Uru ruhererekane rwibipimo byerekana kwizerwa cyane, intera nini ya voltage ikora nigihe kirekire.DC na AC birahari kugirango bikoreshwe.
Ibipimo bya tekiniki
Ikigereranyo cya voltage | DC / AC 98V ~ 242V |
Umucyo mwinshi | > 40 cd / ㎡ |
Imbaraga zumuriro zihanganira voltage | 2kV / 1min |
Kurwanya insulation | ≥100MΩ |
Gukwirakwiza ingufu | ≤1W |
Ubushyuhe bwo gukora | -15 ℃ kugeza + 50 ℃ |
Ubuzima | > Imyaka 10 |
Erekana imikorere | Imiterere yakazi igaragazwa nibara ritukura / icyatsi n'ibishushanyo (Nkuburyo bw'abakiriya) |
Urwego rw'urucacagu: | 37.5 × 37.5 × 62 (mm) |
Ingano yo gutema: | Φ25 (mm) |
Icyitegererezo | Ibisobanuro |
GPWZ25-K / 2 | Umwanya Icyerekezo-Umuzenguruko-Kumena |
GPWZ25-E / 1 | Ikimenyetso cyumwanya-Guhindura isi |
GPWZ25-B / 2 | Ikibanza cyerekana-Ikamyo |
GPWZ25-B / 1 | Umwanya werekana umwanya-uhuza |
GPWZ25-K / 1 | Ikimenyetso cyumwanya-Imyanya itatu Hindura |
Umwanya werekana Mugaragaza GPAS-72
Umwanya wa GPAS-72 yerekana ecran yerekana LED nkisoko yumucyo, hamwe ningufu nkeya, kwizerwa cyane, ubuzima bwa serivisi ndende, nibindi. Kandi irashobora gukoreshwa muburyo bwose bwo guhinduranya ibintu nkibibanza byerekana ecran hamwe nibisubizo bitandukanye bya sisitemu.Hamwe nimirimo myinshi yerekana icyiciro cya voltage yerekana, guhuza, ubushyuhe & kugenzura ubushyuhe, kwerekana umwanya wikiganza, kwerekana imiterere yumuzunguruko, kwerekana imiterere yisi, kwerekana ingufu zabitswe.Nibyiza guhitamo gusimbuza gakondo imwe ihindura leta yerekana imyanya.
Ibipimo bya tekiniki
Ikigereranyo cya voltage | AC / DC 110V / 220V |
Imbaraga zumuriro zihanganira | 2kV / min |
Ibidukikije | -25 ℃ kugeza 55 ℃, ≤ 90% RH |
Ikigereranyo cyerekana urumuri rumurika | > 40cd / m2 |
Ubuzima bw'akazi | Imyaka 10 |
Urwego rwo kurinda | IP42 |
Igipimo | 199x146x63mm |
Ingano yo gutema | 177x121mm |
Ibipimo bya tekinikeGpj-3100 Urukurikirane rugufi ruzenguruka hamwe nisi yerekana amakosa
GPJ-3100 yuruhererekane rwumuzunguruko mugufi hamwe nisi yerekana ikosa ryakozwe mugupima no kwerekana imirongo migufi hamwe nisi yisi mugihe nyacyo.Irakoreshwa mugukurikirana umuziki muri RMU, umurongo wo hejuru, umurongo wo gukwirakwiza amashanyarazi, agasanduku k'ubwoko bwa transformateur nahandi hantu hasa.Ukurikije ibimenyetso byerekana ibimenyetso byerekanwe, abakozi barashobora kumenya no guca ahantu hacyeye mugihe mugihe gito cyumuzunguruko cyangwa ikosa ryisi bibaye mumuzunguruko, sisitemu rero irashobora kugarura amashanyarazi kubutaka butari amakosa vuba kugirango ikoreshe igihe kandi yongere imikorere.
Amakuru ya tekiniki
1. Umuyoboro mugufi uteye ubwoba: 100A kugeza 1000A gutinda 40ms
2. Ubutaka buteye ubwoba: 20A, 30A, 40A, 50A, 60A ± 10% gutinda 40ms
3. Ubushyuhe: -25 kugeza +70 ℃
4. Ubushuhe: ≦ 95%
5. Uburebure bw'isi burebure: 4m
6. Kora fibre optique ifite uburebure bwa 3.5m
7. Amashanyarazi: batiri ya lithium 3.6V / 2.45Ah
8. Auto-reset time: 7s, 2hs, 4hs, 8hs
9. Ibisohoka bisohoka: 120 V AC 1A, 30V DC 2A
10.Igipimo kinini kigenzura: 95x50x80mm
11.Gucamo umwobo: 91x44 mm
12.Icyiciro cyo kurinda: Umugenzuzi mukuru: IP40, Sensor: IP65