40.5kV Hanze ya Vacuum Yumuzunguruko
Incamake y'ibicuruzwa n'imikoreshereze
ZW7A-40.5: CT yubatswe cyangwa hanze, kandi insulasiyo yo hanze ni isura igaragara ya reberi ya silicone cyangwa farufari.
![1](http://www.gpswitchgear.com/uploads/127.jpg)
![2](http://www.gpswitchgear.com/uploads/220.jpg)
![3](http://www.gpswitchgear.com/uploads/317.jpg)
Icyitegererezo cyibicuruzwa nubusobanuro
![4](http://www.gpswitchgear.com/uploads/415.jpg)
Imiterere y'akazi
Imikoreshereze isanzwe
a.Ubushyuhe bwikirere bwikirere, byibuze -30 °, ntarengwa + 40 °;impuzandengo y'ubushyuhe yapimwe mu masaha 24 ntabwo irenga 35 °;
b.Uburebure ntiburenga 1000m;
c.Urwego rwo guhumanya ikirere gikikije ntirushobora kurenga urwego rwa II;
d.Umwuka ukikije ntabwo bigaragara ko wanduye n'umukungugu, umwotsi, gaze yangirika cyangwa yaka umuriro, amavuta cyangwa spray y'umunyu;
e.Umubyimba wibara ntushobora kurenga 20mm;
f.Umuvuduko wumuyaga nturenze 34m / s;
g.Ibice by'imitingito ntibirenza dogere 8;
h.Ubushuhe:
Impuzandengo yubushuhe bugereranije bwapimwe muri 24h, ntiburenga 95%;
Impuzandengo yikigereranyo cyumuvuduko wamazi wapimye muri 24h nturenza 2.2kPa;
Impuzandengo ya buri kwezi ugereranije n'ubushuhe ntiburenga 90%;
Impuzandengo ya buri kwezi umuvuduko wamazi wamazi nturenza 1.8kPa;
Niba ibintu byavuzwe haruguru bisanzwe bikoreshwa birenze, nyamuneka ubaze uwabikoze mbere, kandi nyamuneka ugaragaze igihe utumiza;
Imikoreshereze idasanzwe
Harimo ibidukikije bikoreshwa cyane nkubutumburuke buri hejuru ya metero 1000, ihinduka ryubushyuhe bwihuse, igicucu kiri hejuru ya 20mm, umwanda mwinshi, ubukonje bukabije, mildew, umucanga, umukungugu, ubukonje bukabije, ubushyuhe bukabije, vibrasiya, ingaruka, swing, nibindi, nyamuneka mubiganireho imbere mugihe utumiza.
Ibyingenzi Byibanze Byibanze bya Zw7 Ibicuruzwa
Oya. | Ibisobanuro | Igice | Amakuru | ||
1 | Ikigereranyo cya voltage | kV | 40.5 | ||
2 | 1min Ikigereranyo cyingufu zingana na voltage 1min | kV | 95 | ||
3 | Ikigereranyo cyumurabyo cyihanganira voltage | kV | 185 | ||
4 | Ikigereranyo cyagenwe | Hz | 50 | ||
5 | Ikigereranyo cyubu | A | 630, 1250, 1600, 2000, 2500 | ||
6 | Ikigereranyo kigufi-cyihangane nubu | kA | 20 | 25 | 31.5 |
7 | Ikigereranyo cyo hejuru cyihanganira ikigezweho | 50 | 63 | 80 | |
8 | Ikigereranyo kigufi-kizunguruka kumeneka | 20 | 25 | 31.5 | |
9 | Ikigereranyo kigufi-kizunguruka gikora amashanyarazi | 50 | 63 | 80 | |
10 | Ikigereranyo kigufi-cyumwanya | s | 4 | ||
11 | DC ibice byapimwe bigufi-bizunguruka kumeneka |
| 51 | ||
12 | Agaciro keza ka voltage yigihe gito (TRV) | kV | 114 | ||
13 | Ikigereranyo cyo gutanga amashanyarazi voltage yo gufunga no gufungura ibikoresho hamwe nizunguruka zifasha | V | DC / AC 220V , DC / AC 110V | ||
14 | Urutonde rukurikirana |
| O-0.3s-CO-15s-CO | ||
15 | Igihe cyo gufungura | ms | 20 ~ 50 | ||
16 | Igihe cyo gusoza | 30 ~ 80 | |||
17 | DC igihe gihoraho cyateganijwe kigufi-cyumuzingi kumeneka | 45 | |||
18 | Ikigereranyo cya kabili yishyuza kumena amashanyarazi | A | 50 | ||
19 | Ubuzima bw'umurimo |
| E2-C2-M2 (10000) | ||
20 | Ikigereranyo kigufi-kizunguruka kumena ibihe byacitse | Ibihe | 20 |
Inteko yo Guhindura Ibipimo Imbonerahamwe ya Zw7 Ibicuruzwa
Oya. | Ibisobanuro | Igice | Amakuru |
1 | Menyesha intera yo gufungura | mm | 20 ± 2 |
2 | Menyesha ubwonko | 4 ± 1 | |
3 | Impuzandengo yo gufunga umuvuduko (guhuza ibipimo mbere yo gufunga 10mm mbere yo gufunga) | m / s | 0.8 ± 0.3 |
4 | Impuzandengo yo gufungura umuvuduko (guhuza ibipimo bigabanijwe kuri 10mm zitandukanye) | 1.6 ± 0.3 | |
5 | Bounce igihe cyo gufunga | ms | ≤5 |
6 | Bounce igihe cyo gufunga | ≤2 | |
7 | Gufatanya-pole eshatu gufungura mubihe bitandukanye | ≤2 | |
8 | Inzira nyamukuru irwanya buri pole | μΩ | ≤100 (Nta guhinduranya ibikoresho) |
9 | Icyitonderwa: Ibipimo byavuzwe haruguru bivuga voltage ikora |
Ibipimo byo Kwinjiza
Ku butumburuke bwa metero 1000 (hagati ya 710mm), ubutumburuke bwa metero 2000 (intera iri hagati ya 780), n'uburebure bwa metero 3000 (intera iri hagati ya 850), ibipimo rusange yo kumena inzitizi niyi ikurikira:
![5](http://www.gpswitchgear.com/uploads/515.jpg)
Ku butumburuke bwa metero 4000 (hagati hagati 920), kuri metero 5000 (intera hagati ya metero 1000), ibipimo rusange bya kumena inzitizi ni ibi bikurikira:
![6](http://www.gpswitchgear.com/uploads/614.jpg)