GPN1-40.5kV Ikurwaho AC Ibyuma byambaye ibyuma bifunze
Incamake
GPN1-40.5kV ikurwaho AC icyuma cyambaye ibyuma (bigufi kuri switchgear nkuko biri hepfo) ikoreshwa kuri 40.5kV, icyiciro 3, AC na 50 / 60Hz umuyagankuba wo kwakira no gukwirakwiza ingufu z'amashanyarazi ndetse no kugenzura, kugenzura no kurinda.Irakoreshwa muri sisitemu yimbaraga rusange nibihe hamwe nibikorwa kenshi.Igicuruzwa gihuye na GB 3906 “3 ~ 35kV AC Metal Enclosed Switchgear”, GB / T 11022 “Ingingo rusange ya tekinike ya High Voltage Switchgear and controlgear Standard”, DL / T 404-1997 “Tegekanya igihe cya tekiniki yo mu nzu AC Yihuta cyane. ”Na IEC-298“ 1 ~ 52kV AC Metal Ifunze Guhinduranya no Kugenzura ”.
Imiterere y'ibidukikije
Ubushyuhe bwibidukikije: -25 ℃ ~ + 45 ℃, impuzandengo ya buri munsi: ≤35 ℃
Uburebure: 1000m (Bisanzwe);irashobora kugera kuri 4500m yo gutumiza bidasanzwe;
Ubushuhe bugereranije: impuzandengo ya buri munsi ≤ 95%, impuzandengo ya buri kwezi ≤ 90%;
Imbaraga z'umutingito dogere8;
Ibihe byakoreshwa bigomba kuba bitarangwamo ruswa, ibicanwa n'umwuka.
Icyitegererezo
![img1](http://www.gpswitchgear.com/uploads/img19.jpg)
Ibiranga ibicuruzwa
Switchgear nigice cyiteranirizo kandi icyuma cyumuzunguruko gifata icyitegererezo cyintoki.Ifite impinduka gusa no guhanahana neza nyuma yogukoresha ibikoresho bigizwe na insuline ya vacuum yamashanyarazi.Uburyo bwa sisitemu yo gusunika ibinyomoro byashyizwe mumashini yintoki kugirango wirinde gukora amakosa no kwangiza uburyo bwo kugenda, ikarita irashobora gukurwaho byoroshye;Intambwe zose zo gukora zirashobora gukorwa mugihe cyo gufunga;Nugukingirwa byanze bikunze hagati yingenzi, ikarita yintoki hamwe numuryango wumuryango kugirango ubone uburinzi butanu;umwanya mugari wo guhuza insinga nyinshi muri kabili cubicle.Ihinduramiterere ryubutaka rikoreshwa mubutaka no kuzunguruka bigufi, urwego rwo kurinda uruzitiro ni IP3X, IP2X mugihe cyo gufungura.
Ibisobanuro bya tekiniki
Oya. | Ingingo | Igice | Amakuru | |
1 | Ikigereranyo cya voltage | kV | 36/38 / 40.5 | |
2 | Ikigereranyo cyubu | A | 1250, 1600, 2000, 2500 | |
3 | Ikigereranyo cyagenwe | Hz | 50/60 | |
4 | Ikigereranyo kigufi cyumuzunguruko | kA | 25, 31.5 | |
5 | 4s yagenwe igihe gito kwihanganira ikigezweho | kA | 25, 31.5 | |
6 | Ikigereranyo kigufi cyumuzingi ukora amashanyarazi (impinga) | kA | 63, 80 | |
7 | Ikigereranyo cyo hejuru cyihanganira ikigezweho (impinga) | kA | 63, 80 | |
8 | Urwego | Ikigereranyo cyumurabyo cyihanganira voltage | kV | 185 (unyuze kumugaragaro: 215) |
Inzira nyamukuru 1min yumurongo wumurongo wihanganira voltage | kV | 95 (hakurya yugurura: 110) | ||
Umufasha wumuzunguruko 1min imbaraga yumurongo wihanganira voltage | kV | 2 | ||
9 | Ibipimo byerekana (W) * (D) * (H) | mm | 1400/2800/2600 (Ubwoko bwa GPN1) 1200/2600/2400 (Kubwoko bwa VD4 / HD4) | |
10 | Impamyabumenyi yo gukingira | IP3X (igice IP2X) | ||
11 | Ibiro | kg | 1000-1850 (ubwoko bwa GPN1) 850-1850 (Kubwoko bwa VD4 / HD4) |
Imiterere Imiterere
Amashanyarazi agabanyijemo ibice hamwe nintoki, uruzitiro rukozwe mu rupapuro rwa aluminium-zinc rwometseho ibyuma nyuma yo gutunganywa n’imashini ya CNC no kugoreka byinshi, hanyuma igateranyirizwa hamwe na bolts.Ifite imbaraga zikomeye za mashini kandi irashobora kwemeza ubwiza nuburyo bugaragara.Igizwe na relay compartment, handcart compartment, kabel kabili, impamyabumenyi yo gukingira ni IP2X mugihe ikarita ya CB iri gufungura no kugerageza.
Switchgear nicyuma cyambuwe ubwoko bwakuweho, umuzenguruko nyamukuru ukoresha uburyo bwo gutunganya ibintu, byihutirwa bikwira mubindi bice.CT hamwe nubutaka bwashyizwe mubice bya kabili hamwe na busbar.Urwego rwo kurinda uruzitiro ni IP3X, kurinda n'umwanya munini w'insinga nyinshi.Igishushanyo mbonera gishya cya VCB cyangwa SF6 CB hamwe nuburyo bwo gukora amasoko byahujwe na moderi ya konsole hamwe nibyiza byo guhanahana neza no guhinduka gusa.
Urucacagu Igipimo cya Switchgear
![img2](http://www.gpswitchgear.com/uploads/img25.jpg)
![img3](http://www.gpswitchgear.com/uploads/img33.jpg)