GPVN-40.5kV Imbere mu nzu AC Umuvuduko mwinshi wa Vacuum Inzira
Imiterere y'ibidukikije
Uburebure: 1000m (Bisanzwe);irashobora kugera kuri 4500m yo gutumiza bidasanzwe;
Ubushyuhe bwibidukikije: -25 ℃ ~ + 45 ℃;
Ubushuhe bugereranije: impuzandengo ya buri munsi ≤95%, impuzandengo ya buri kwezi ≤ 90%;
Imbaraga z’umutingito: dogere 8;
Ibihe bishobora gukoreshwa bitarimo ibicanwa, ibisasu, ruswa hamwe no kunyeganyega gukabije.
Icyitegererezo
![7](http://www.gpswitchgear.com/uploads/78.jpg)
Imiterere Imiterere
1. Urugereko rwa arc-kuzimya ruri ku gice cyo hejuru kandi uburyo buri ku gice cyo hasi.Iyi miterere iroroshye gukemura.
2. Imiterere igoye ikoresheje umwuka hamwe nibikoresho kama;Ibipimo byoroheje n'uburemere buto.
3. Vacuum arc-kuzimya urugereko rwa Cutler-Nyundo (USA) na ZMD yo murugo byombi birakoreshwa kuri VCB.Ubwoko bubiri bwibyumba bizimya arc ukoresheje vertical magnetique yumurima kandi ugaragaramo gukata gake hamwe nubushobozi bwiza kuri off-off hamwe na asimmetrie.
4. Uburyo bworoshye bwo gukora amasoko ntibubungabungwa mugihe 10000 cyibikorwa.
5. Icyuma-cyogosha icyuma, imikorere yoroshye kandi ihamye hamwe nubushobozi bwiza bwo kwifungisha.
Ibisobanuro bya tekiniki
Oya. | Ingingo | Igice | Amakuru |
1 | Ikigereranyo cya voltage | kV | 36/38 / 40.5 |
2 | 1min.Imbaraga zumuriro zihanganira voltage | kV | 95 (118, gutandukanya intera) |
3 | Inkuba irashobora kwihanganira voltage (impinga) | kV | 185 (215 gutandukanya intera) |
4 | Ikigereranyo cyubu | A | 630,1250.1600.2000, 2500 |
5 | Ikigereranyo kigufi-kizunguruka kumeneka | kA | 20, 25, 31.5 |
6 | Ikigereranyo kigufi-kizunguruka gikora amashanyarazi (impinga) | kA | 50, 63, 80 |
7 | 4s yagenwe igihe gito kwihanganira ikigezweho | kA | 20, 25, 31.5 |
8 | Ikigereranyo cyo hejuru cyihanganira ikigezweho | kA | 50, 63, 80 |
9 | Urutonde rukurikirana | O-0.3s-CO -180s-CO | |
10 | Kumena ibihe byateganijwe bigufi byumuzunguruko | Ibihe | 30 |
11 | Ubuzima bwa mashini | Ibihe | 10000;20000 (kubwoko bwa magneti) |
12 | Ikigereranyo cyagenwe | Hz | 50/60 |
13 | Ikigereranyo cyo kumena amashanyarazi ya banki | A | 400 |
Tekiniki ya tekinike yo kubika moteri yububiko bukoreshwa
Oya. | Ikigereranyo cya voltage | Ikigereranyo gisohoka imbaraga | Ubusanzwe ikora voltage | |
HDZ-22301B | DC110V AC110V | DC220V AC220V | 30230W | 85% -110% byapimwe voltage |
Urucacagu nubunini bwubushakashatsi
![8](http://www.gpswitchgear.com/uploads/86.jpg)
![9](http://www.gpswitchgear.com/uploads/96.jpg)
Igishushanyo cya kabiri
![10](http://www.gpswitchgear.com/uploads/108.jpg)